Panel Mount Plunger Basic Switch

Short Description:

Renew RZ-15GQ-B3 / RZ-15HQ-B3 / RZ-15EQ-B3 / RZ-01HQ-B3 / RZ-15GQ8-B3

● Ampere Rating: 15 A / 0.1 A
● Contact Form: SPDT / SPST


  • High Precision

    High Precision

  • Enhanced Life

    Enhanced Life

  • Widely Used

    Widely Used

General Technical Data

Product Tags

Product Description

Featuring a panel mount plunger actuator, this switch is designed for easy integration into control panels and equipment housings. Use the attached hexagonal nuts and lock nuts to mount the switch to a panel and to adjust mounting position. Permitted actuation by a low velocity cam and widely used in elevators and lifting equipment.

1.RZ-15GQ-B3
2.RZ-15GQ8-B3

Dimensions and Operating Characteristics

Panel Mount Plunger Basic Switch cs

General Technical Data

Rating RZ-15: 15 A, 250 VAC
RZ-01H: 0.1A, 125 VAC
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance RZ-15: 15 mΩ max. (initial value)
RZ-01H: 50 mΩ max.(initial value)
Dielectric strength Between contacts of same polarity
Contact gap G: 1,000 VAC, 50/60 Hz for 1 min
Contact gap H: 600 VAC, 50/60 Hz for 1 min
Contact gap E: 1,500 VAC, 50/60 Hz for 1 min
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min
Vibration resistance for malfunction 10 to 55 Hz, 1.5 mm double amplitude (malfunction: 1 ms max.)
Mechanical life Contact gap G, H: 10,000,000 operations min.
Contact gap E: 300,000 operations
Electrical life Contact gap G, H: 500,000 operations min.
Contact gap E: 100,000 operations min.
Degree of protection General-purpose: IP00
Drip-proof: equivalent to IP62 (except terminals)

Application

Renew’s basic switches play a critical role in ensuring the safety, precision, and reliability of various devices across different fields. Here are some popular or potential application.

product-description2

Elevators and lifting equipment

Installed at each floor position in the elevator shaft to send a floor position signal to the control system and ensure precise floor stopping. Used to detect the position and status of the elevator safety gear, ensuring the elevator can stop safely in an emergency.

product-description1

Industrial Machinery

Used in industrial applications such as industrial air compressors and hydraulic and pneumatic systems to limit the maximum movement for pieces of equipment, ensuring precise positioning and safe operation during processing.

product-description2

Valves and Flow Meters

Employed on valves to monitor the position of the valve handle by indicating if the switch is actuated. In this case, basic switches perform position sensing on cams with no power consumption.